Products - Sinetec Technologies
Oscilloscpe,Analyzers,meters -Oscilloscope Accessories
Product Description Compatible Oscilloscopes Compatible Probes Description
U1570A AC power adapter
The U1570A AC Power Adapter is to be used with the U1600A series handheld scopes. U1600A Handheld Series n/a The U1570A AC Power Adapter is to be used with the U1600A series handheld scopes.
1180CZ Testmobile Scope Cart
n/a DSO1000 Series DSO3000 Series DSO5000 Series DSO6000 Series MSO6000 Series n/a The Agilent 1180CZ testmobile scope cart provides convenient mobility of test equipment to make them readily available when needed and effectively extend the amount of lab bench space. The 1180CZ allows several operators to cost effectively share expensive equipment.
U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes
Ni-MH battery pack for the 1600A Series scopes U1600A Handheld Series n/a Description The Agilent U1571A Ni-MH battery pack is compatible with the U1600A Series Handheld Digital Oscilloscope. Ni-MH Battery Pack, 4500mA
N2732A Rack Mount Kit for the 7000 Series Oscilloscopes
Rack mount kit for the 7000 Series oscilloscopes DSO7000 Series MSO7000 Series n/a The Agilent N2732A provides a 7U-high rack mount kit for Agilent InfiniiVision 7000 Series oscilloscopes. The kit installs in less than 1 hour and the rack tray includes a secure pouch for keeping mechanical parts not needed when the scope is rack mounted. Looking for a solution that takes less vertical space? Consider the 5U-high Infiniivision 6000 Series oscilloscopes with N2916B rackmount kit- Infiniivision 6000 Series
U1580A DMM Terminal Test Lead
Test leads compatible with the U1600A Series scopes U1600A Handheld Series n/a The Agilent U1580A test leads are compatible with the U1600A Series Handheld Digital Oscilloscope Probes and Test Leads. These test leads are used for the DMM terminal on these oscilloscopes.
N2733B Soft Carrying Case
Soft carrying case for large-screen InfiniiVision Series oscilloscopes DSO7000 Series MSO7000 Series DSO4000 X-Series MSO4000 X-Series n/a The N2733B Soft carrying case is the perfect way to travel with or store your InfiniiVision Series oscilloscope. The case is designed for convenience with padded sides and bottom, as well as a storage pouch for your probes and additional accessories.
U1583B AC Current Clamp
Current clamp allows you to take readings without breaking the circuit being measured U1600A Handheld Series n/a The U1583B current clamp is your dual range AC current clamp to enable taking current readings without breaking the circuit being measured. Its 40A and 400A dual range gives you the flexibility you need in a single instrument, to be used on either an Agilent handheld digital multimeter or handheld oscilloscope.
N6457A Soft carrying case and front panel cover for 2000 and 3000 X-Series oscilloscope
Soft carrying case and front panel cover for the InfiniiVision 2000 and 3000 X-Series oscilloscopes DSO2000 X-Series MSO2000 X-Series DSO3000 X-Series MSO3000 X-Series n/a The N6457A Soft carrying case is the perfect way to travel with or store your 2000 or 3000 X-Series oscilloscope. The case is designed for convenience with padded sides and bottom, as well as a storage pouch for your probes and additional accessories. When you order N6457A, you also receive the durable front panel cover to protect your oscilloscope during transport.
N2747A Front Panel Cover for the InfiniiVision 2000 and 3000 X-Series oscilloscope
Stand-alone Front panel cover for the 2000 and 3000 X-Series Oscilloscope DSO2000 X-Series MSO2000 X-Series DSO3000 X-Series MSO3000 X-Series n/a The N2747A Front panel cover protects your oscilloscope during storage and transport. The cover ensures that the high resolution display, the input channels and knobs will be protected.
N6456A Rack Mount Kit for the InfiniiVision 2000 and 3000 X-Series oscilloscope
Rack Mount Kit for the 2000 and 3000 X-Series oscilloscopes DSO2000 X-Series MSO2000 X-Series DSO3000 X-Series MSO3000 X-Series n/a Description The Agilent N6456A provides a rack mount kit for the InfiniiVision 2000 and 3000 X-Series oscilloscopes. The kit installs in less than 1 hour and the rack tray includes a secure pouch for keeping mechanical parts not needed when the scope is rack mounted.
DSOXLAN LAN/VGA module for the InfiniiVision 2000 and 3000 X-Series Oscilloscope
LAN/VGA module for the InfiniiVision 2000 and 3000 X-Series Oscilloscope DSO2000 X-Series MSO2000 X-Series DSO3000 X-Series MSO3000 X-Series n/a LAN/VGA module gives you network connectivity and complete LXI class C support as well as the ability to connect to an external monitor. Operate your scope remotely from your PC using the web browser interface with the virtual front panel interface that looks and acts as the real front panel on the scope with the same associated keys and knobs. Oscilloscope are required.
DSOXGPIB GPIB connection module for the InfiniiVision 2000 and 3000 X-Series oscilloscope
GPIB connection module for the InfiniiVision 2000 and 3000 X-Series oscilloscopes DSO2000 X-Series MSO2000 X-Series DSO3000 X-Series MSO3000 X-Series n/a http://www.home.agilent.com/agilent/redirector.jspx?action=obs&nid=-33523.3.00&lc=eng&cc=IN&ckey=2002854&pubno=5990-6618EN<ype=LitStation&ctype=AGILENT_EDITORIAL
U1586B Temperature Module
Temperature adapter for the U1600B Series scopes U1600A Handheld Series n/a The U1586B temperature adapter expands the capabilites of your handheld oscilloscope or handheld digital multimeter to measure temperature, either in of To be used with a K-type bead thermocouple, and with approximately 1600 hours battery life with an alkaline battery, this adapter ensures you get the most out of your handheld scope or DMM purchase.
E2646B Signal Quality Inrush Droop/Drop (SQuIDD) for Low/Full Speed Testing
E2646B Signal Quality inrush Droop/Drop (SQuIDD) for low/full speed testing DSO8000 Series MSO8000 Series DSO80000B Series DSO9000 Series MSO9000 Series DSO90000A Series DSA90000A Series n/a SQuIDD (signal quality inrush, drop/droop) test fixture for: Full-speed signal quality testing Low-speed signal quality testing Inrush current testing Host and Hub droop/drop testing (also requires the E2649-66405 Droop/Drop test fixture) Required for N5416A USB 2.0 compliance test software. Compatible with Infiniium 8000, 9000, 80000 and 90000 Series oscilloscopes.
U1590A Carrying Case - Soft
Soft carrying case for the U1600A Series scopes U1600A Handheld Series n/a The Agilent U1590A soft carrying case provides storage for U1600A Series Handheld Digital Oscilloscopes and all its standard accessories.
N2916B Rack Mount Kit for 5000 and 6000 Series Oscilloscopes
Rackmount kit for 5000/6000 Series DSO5000 Series DSO6000 Series MSO6000 Series n/a Description The Agilent N2916B provides a support shelf and necessary hardware for mounting Agilent 5000 and 6000 Series oscilloscope into EIA standard 19-inch rack cabinets. The rack mount kit comes in at 5U (8.75 inch) height.
N2917B Transit Case for 5000 and 6000 Series Oscilloscopes
Carrying case for 5000/6000 Series DSO5000 Series DSO6000 Series MSO6000 Series n/a The Agilent N2917B carrying case makes transporting and shipping your 5000 and 6000 family oscilloscope safe and simple. A scope, optional module and other accessories fit neatly inside the padded shell of hard plastic and the case is lockable for shipment.
N2919A Testmobile Bracket for 6000 Series Scope and 1180CZ TestMobile
Testmobile bracket for 1180CZ and 6000 Series DSO6000 Series MSO6000 Series n/a For use with the 6000 Series oscilloscope and the 1180CZ testmobile scope cart, the N2919A testmobile bracket provides secure mounting of your scope on the 1180CZ testmobile.
E2697A High Impedance Adapter (includes 500 MHz passive probe)
High Impedance Adapter for 50 ohm input oscilloscope (includes 500MHz passive prove) n/a 1130A, 1131A, 1132A, 1134A, 1168A, 1169A The E2697A high impedance adapter allows connection of probes that require a high impedance input (e.g., passive probes, current probes) to the Infiniium 54850, 80000 and 90000 Series of high performance oscilloscopes. The E2697A high impedance adapter extends the capability of Agilent Infiniium high-performance oscilloscopes, making them ideal for a variety of general-purpose measurements such as power supplies, inverters, semiconductor devices, etc. The E2697A provides switchable ac/dc coupling, as well as 10:1 and 1:1 attenuation settings.
DSO6012-BAT Battery-Power Option for all 6000 Series Models
Battery power option for the 6000 Series scopes DSO6000 Series MSO6000 Series n/a Agilent 6000 series offers the industry,s first battery-powered oscilloscopes with bandwidths up to 1 GHz. Based on lithium-ion technology, the rechargeable battery use model is similar to a traditional laptop PC. The battery charges while plugged in to line power and can be disconnected at any point in time without powering off the oscilloscope. Fully charged, the battery option provides more than two hours of battery life between charges. Plugged into 12-V automotive outlets, Agilent’s N5429A adapter cable enables oscilloscopes equipped with the battery option to operate simultaneous with battery charging.
U1880A Power measurement deskew fixture
Power measurement deskew fixture for voltage and current probes DSO6000 Series MSO6000 Series DSO7000 Series MSO7000 Series DSO8000 Series MSO8000 Series DSO9000 Series MSO9000 Series n/a For accurate power measurements, it is extremely important to equalize the time delay between voltage and current probes. The U1880A deskew fixture allows you to drive both your voltage and current probes with the same pulse signal. Probe deskew can then be performed with the power measurements application software, or may be performed manually on the oscilloscope.
W2635A and W2636A DDR3 BGA Probe Adapter
DDR3 BGA probe adapters DSO80000B Series DSO90000A Series DSA90000A Series n/a The Agilent Technologies W2635A and W2636A DDR3 BGA probe adapters provide signal access to the clock, strobe, data, address and command signals to the DDR3 BGA package for making electrical and timing measurements with an Infiniium oscilloscope. With the DDR3 JEDEC specification (JESD79-3A) defined at the DRAM ballout, the BGA probe adapter provides direct signal access to BGA package for true compliance testing. The W2635A and W2636A DDR3 BGA probe adapters are soldered in between the DRAM and PC board or DIMM raw card where the DRAM would normally be soldered. They are designed with the PCB or DIMM foot print on the bottom side and the DRAM footprint on the top side. The signals from the memory controller chip and DRAM are then passed directly to the top side of the BGA probe adapter where they can be accessed with the oscilloscope probes.
W2642A DisplayPort AUX Channel Controller
n/a DSO80000B Series DSO90000A Series n/a The Agilent W2642A DisplayPort AUX Channel Controller implements the DisplayPort Automation capability enabled by the DisplayPort standard. For Source test, the W2642A is controlled by the U7232A DisplayPort Source Compliance Test software to control Source devices to the configurations necessary for each test. For Sink compliance test, the N5990A Factory Automation software controls the N4903A and the W2642A to stimulate and control sinks. The W2642A and the W2642A Graphical User Interface can also be used for general purpose device validation by reading and writing or controlling EDID and Configuration data.
N1027A Oscilloscope Accessories for DCA family
The Agilent 1143A provides power and independent offset control for two Agilent 54700-series probes. n/a 54701A N1027A is a collection of accessories for mainframes and modules in the 86100 family of Digital Communication Analyzers (DCAs). The accessories can be grouped into: Kits including multiple parts for specific applications (e.g., N1027A-45A for the N1045A 60 GHz Electrical Remote Sampling Heads) Individual components needed for measurements (e.g., N1027A-PT2/PT3 phase trimmers to adjust skew between electrical channels) Items for protection and storage (e.g., N1027A-1MC storage case for mini-modules with remote heads)
N2763A Rack Mount Kit for the 4000 X-Series Oscilloscopes
n/a n/a n/a The Agilent N2763A provides a 7U-high rack mount kit for Agilent InfiniiVision 4000 X-Series oscilloscopes. The kit installs in less than 1 hour and the rack tray includes a secure pouch for keeping mechanical parts not needed when the scope is rack mounted.
E2655C Probe deskew and performance verification kit
Probe deskew and performance verification kit for InfiniiMax probes. 1130A 1131A 1132A 1134A 1168A 1169A n/a A probe deskew and performance verification kit for use with InfiniiMax probes. The E2655C is a replacement of the E2655B. The E2655B is discontinued, but it will be supported until March 2018.
N1022B Probe Adapter
The N1022B TDR calibration kit contains precision devices to calibrate the measurement path. 86100 Series DSO90000 Series n/a Waveform analysis of high-speed electrical circuits is made easier and significantly more accurate with the Agilent InfiniiMax 1130 series of high-performance active probes. These probes, along with the Agilent 115X probe family can now be used with the 86100 Infiniium digital communications analyzer (DCA) series of wide-bandwidth sampling oscilloscopes. The N1022B probe adapter provides power, identification/calibration, and a high-integrity signal path between the DCA plug-in module and the probe. The output/interface end of the probe amplifier section attaches to one side of the adapter. The other side of the probe adapter is an instrumentation grade 3.5 mm connector that attaches to the bulkhead male connector of the electrical channel on the oscilloscope plug-in module. For bias and identification, an interface cable from the probe adapter attaches to the probe power port of the oscilloscope plug-in. The N1022B is directly compatible with any of the 861XX, 8348X, and 5475X DCA plug-in modules with electrical channel bandwidths of 20 GHz or less and a 3.5 mm connector.
N1024B TDR Calibration Kit
The N1024B TDR calibration kit contains precision devices to calibrate the measurement path. 86100 Series DSO90000 Series n/a Todays high-speed circuits require accurate measurements and accurate measurements require accurate standards.The Agilent N1024B TDR calibration kit contains precision standard devices based on SOLT (Short-Open-Load-Through) technology to calibrate the measurement path. This 3.5 mm kit also contains a torque wrench for proper connection technique.
N2744A T2A probe interface adapter
The N2744A T2A interface adapter enables selected Tektronix TekProbe® interface level II probes to be used with Agilent oscilloscopes with AutoProbe interface. DSO5000 Series DSO6000 Series MSO6000 Series DSO7000 Series MSO7000 Series DSO9000 Series MSO9000 Series DSO90000A Series DSA90000A Series DSO3000 X-Series MSO3000 X-Series DSO4000 X-Series MSO4000 X-Series n/a The N2744A T2A interface adapter enables selected Tektronix TekProbe® interface level II probes to be used with Agilent oscilloscopes with the AutoProbe interface. Existing TekProbe-BNC probe types can simply be plugged into the T2A adapter which is then plugged directly into any AutoProbe input channel on an InfiniiVision or Infiniium oscilloscope. Select the probe model in the scope menu and the Agilent oscilloscope sets up the attenuation factor and the probe type automatically. The T2A interface adapter supplies the necessary probe power. Calibration (for select models only) and offset control as used by the connected TekProbe probe. Tektronix, Tek and TekProbe® are registered trademarks of Tektronix, Inc.
N4866A PCI Express High Speed Interconnect
PCI Express High Speed Interconnect for Infiniium 90000 Series oscilloscope DSO90000A Series DSA90000A Series n/a The Agilent DSO/DSA90000 Series allows the longest high bandwidth time capture of any oscilloscope on the market. When this capability is combined with the PCI Express® high-speed interconnect card, it allows engineers a capture and analysis up to 4x faster than anything previously available. The Agilent N4866A PCI Express High Speed Interconnect is compatible with Agilent 90000 Series oscilloscopes purchased after December 2009 with operating software revision 1.1 or higher.
N1080B HDMI Test Point Access Adapters
The N1080A HDMI test point access adapters are well suited for testing channel, source and sink characteristics, providing the best rise time, excellent skew and the ability to connect into tight spaces. 86100 Series DSO90000 Series n/a High Definition Multimedia Interface (HDMI) is being rapidly adopted for use on high definition entertainment products, including HD satellite receivers, players, flat panel televisions and computer monitors. Consumers benefit from much richer and higher quality images. Designers and manufacturers are challenged with increasing data rates and color depths, requiring more robust design and measurement tools.
GPIB to LAN adapter for Agilent’s 7000, 9000A and 9000 H-Series oscilloscopes
GPIB to LAN adapter DSO7000 Series MSO7000 Series DSO9000 Series MSO9000 Series n/a Agilent’s N4865A is a GPIB to LAN adapter that provides a GPIB interface for VXI-11.3 compatible LAN based oscilloscopes such as Agilent’s 7000, 9000A and 9000 H-Series. Using the N4865A, GPIB applications running on a computer can transparently interface to a LAN based instrument as if it were a GPIB instrument. The N4865A will not require any custom software or driver on either the controller or the instrument beyond whatever GPIB software is already in use. The product is compatible with the LXI AutoIP standard or can use a static IP address.
USB 3.0 test fixture
U7242A USB 3.0 test fixture DSO90000A Series DSA90000A Series n/a The U7242A USB 3.0 test fixture will help simplify the USB 3.0 measurement process by providing access to the transmitter and receiver measurement points required for USB 3.0 compliance testing. It has been designed for direct SMA connections for easy and accurate measurements with direct connections to the oscilloscope and J-Bert SMA connections. It also includes probing connections for InfiniiMax active differential probes for the characterization and testing of active bus signaling of USB 3.0 and USB 2.0 traffic. Provides test point access for high performance transmitter signal integrity measurements Provides receiver test connections for receiver jitter tolerance testing Convenient plug on probing - Header access to the USB 3.0 and USB 2.0 signal lanes for Differential measurements using active probes allow probing of active bus transactions for debug and verification testing USB 3.0 power probing features for easy measurement of transient and steady state power states For fixture characterization and USB 3.0 test tool information, select the Related Products tab
N2882A 75Ω to 50Ω BNC adapter
BNC adapter for InfiniiMax probes DSO5000 Series DSO6000 Series MSO6000 Series DSO6000L Series DSO7000 Series MSO7000 Series DSO8000 Series MSO8000 Series DSO9000 Series MSO9000 Series DSO90000A Series DSA90000A Series n/a To connect your 75 ohm video signal to the 50 ohm input of a scope without aberrations and reflections, use the Agilent N2882A 75 ohm-to-50 ohm adapter. The N2882A presents up to 8 GHz of bandwidth with flat frequency response and low return loss.
N2902A 9000 Series rackmount kit
Rackmount kit for the 9000 Series oscilloscopes DSO9000 Series MSO9000 Series n/a Description The rackmount kits consists of a support shelf and hardware for mounting the 9000A and 9000 H-Series scopes into an Electronics Association (EIA) standard rack cabinet.
LPDDR BGA probes
n/a n/a n/a The W2637A, W2638A and W2639A LPDDR BGA probes allow you to get complete signal access to the LPDDR and mobile-DDR signals critical to your debug and validation effort with Agilent logic analyzers and oscilloscopes. The LPDDR BGA probes enable viewing of data traffic on industry standards LPDDR SDRAM, LPDDR NVM and mobile-DDR SDRAM. The probe works in existing designs and eliminates the need for up front planning or re-design. The probe connects directly to the balls of the DRAM, enabling you to operate at full speed and acquire high-speed LPDDR signals without impacting the performance of your design. S parameter models are available for use with InfiniiSim for de-embedding purposes. The LPDDR BGA probes also offer BGA probe sockets for easy probe attachment. Information on sockets is available at the following R&D Interconnect Solutions website: http://www.hsiotech.com
1000 Series education training kit
Soft case for 1000 Series oscilloscopes DSO1000 Series n/a The N2740A education training kit provides a demo board designed to simulate a variety of real-world applications. This kits also includes a USB cable and an easy-to-follow user’s manual.
1000A Series rackmount kit
Rackmount kit for the 1000 Series oscilloscopes DSO1000 Series n/a The Agilent N2739A provides a support shelf and necessary hardware for mounting Agilent DSO1000A Series oscilloscope into EIA standard 19-inch rack cabinets. The rack mount kit comes in at 4U (6.94 inch) height.
Soft carrying case for 1000 Series
Soft case for 1000 Series oscilloscopes DSO1000 Series n/a The N2738A soft carrying case is the perfect accessory for storing and carrying your DSO1000 Series oscilloscope. The case is designed for convenience – all of your probes, manuals, and connectors can be stored with your oscilloscope – and the ergonomic design makes it easy to take it all with you.
N5429A 12 V automotive adapter
Adapter for charging and operating the battery-powered 6000 Series scope DSO6000 Series MSO6000 Series n/a The N5429A adapter cable accessory provides charging and operating battery-powered 6000 Series scopes from a 12 V automotive outlet. Unplug the oscilloscope for 2+ hours of operation from battery power between charges.
U3000A Electronic Instrumentation Training Kit
n/a DSO1000 Series DSO3000 Series n/a The U3000A electronic instrumentation training kit is a standalone training board designed to simulate a variety of real-world applications. The kit works seamlessly with four reliable, high-performance instruments and Agilent VEE Pro 8.0 test & measurement software that are widely used in various industries.
E2621A Termination Adapter, 100/110/120 Ohm
E2621A ac-coupled, balanced adapter allows connection to differential communications signals by terminating the signal into 100, 110 or 120 ohms DSO80000B Series n/a The Agilent E2621A ac-coupled, balanced adapter allows connection to differential communications signals by terminating the signal into 100, 110 or120 ohm. It also adapts various connector styles (i.e., bantam, RJ48C and Siemens) to the oscilloscope's 50 ohm; BNC input. You can select the termination impedance using the built-in, three-way switch. The AutoProbe interface allows the Agilent Infiniium oscilloscope to recognize the Agilent E2621A and read the termination switch setting. Furthermore, Agilent Infiniium will flag you when the switch setting differs from the standard's required termination impedance. Bandwidth (-3 dB): less than 10 kHz to greater than 100 MHz Rise Time: less than 3.5 ns Attenuation: 5X (-14 dB) + or - 3% (50 kHz to 30 MHz)
1143A Probe Offset Control and Power Module
The Agilent 1143A provides power and independent offset control for two Agilent 54700-series probes. n/a 54701A The Agilent 1143A provides power and independent offset control for two Agilent 54700-series probes. The probe's offset can be controlled via a 9-pin, D-subminiature connector on the rear panel of the Agilent 1143A. Additionally, the ±50 V offset capability extends the dynamic range of the probe measurement system beyond that of many test and measurement instruments. The Agilent 54701A, with the Agilent 1143A Probe Offset Control and Power Module, is versatile enough to be used with any test and measurement equipment with a 50 ohm input.