Products - Sinetec Technologies
Megger -Insulation resistance testers > 1 kV
Product Description
MIT515
Offering CAT IV, the MIT515 is the simplest of Meggers new range of small light 5 kV insulation resistance testers for the testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.Now equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.
MIT525
As well as measuring insulation resitance to 10 TΩ, the MIT525 also offers various diagnostic tests such as Polarisation index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.Now equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.
MIT1025
Offering CAT IV, the MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.As well as measuring insulation resitance to 20 TΩ, the MIT1025 also offers various diagnostic tests such as Polarisation index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.Now equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.
Megger S1-568
• Proven ability to make accurate stable measurements in noisy environments such as 765kV substations• Rapid charge of capacitive loads such as HV power cables• Additional safety in high energy locations with remote operation• Always ready to test with fast charge Li-ion battery or a.c. source operation• Designed to survive harsh environmentsS1-568 5 kV insulation resistance testers has been designed, specified and tested to meet the stringent requirements of power utilities in the 21st century. In addition to being tough, high performance insulation testers the S1-568 Megger offers the ability to perform accurate insulation resistance measurements in extreme, high noise environments, rapid charging of cable capacitance, and even remote operation for both convenience and safety.
Megger S1-1068
S1-1068 10 kV insulation resistance testers has been designed, specified and tested to meet the stringent requirements of power utilities in the 21st century. In addition to being tough, high performance insulation testers the S1-1068 Megger offers the ability to perform accurate insulation resistance measurements in extreme, high noise environments, rapid charging of cable capacitance, and even remote operation for both convenience and safety. For service companies the S1-1068 represents an excellent choice with its flexibility and future proofing capability. Quite simply the Megger S1-Series is designed to work wherever you work.
IDAX300 and IDAX350
IDAX300 is a very compact instrument and is used together with an external computer. The IDAX350 has a built-in computer but can also be used with an external computer.IDAX300 and IDAX350 provide an accurate and reliable condition assessment of insulation in transformers, bushings, generators and cables. The IDAX system maximizes the outcome of maintenance activities allowing for load and service life optimization.IDAX300 and IDAX350 are smaller, lighter and faster than their predecessor IDA200 and IDAX206. It maintains better accuracy and ability to provide reliable data using true AC DFR (Dielectric Frequency Response), also known as FDS (Frequency Domain Spectroscopy), for reliable test results in high interference environments. The state-of-the-art software makes testing both easier and faster, allowing transformer moisture and oil assessment in about 22 minutes (20°C).
CDAX 605
CDAX 605 is a capacitance and dissipation factor test set to be used with an external power source/generator. It is a precision instrument using a combination of bridge and direct (vector) measurements and is capable of measuring capacitive, resistive and inductive loads.CDAX 605 is designed for laboratory, production line or field testing of electrical equipment insulation and insulating materials as well as e.g. calibration of CCVTs and other ratio devices. A test set with unique high accuracy for the most demanding applications.
VAX020
Separate high voltage amplifier enables capacitance and dissipation factor measurements at 2 kV test voltage True and proven DFR/FDS technology for highest performance Large frequency range, DC to 1 kHz Compact design, weight < 5 kgVAX 020 expands the IDAX test voltage range from 200 V to 2 kV. This improves the capability to perform accurate measurements in extreme high interference environments e.g. HVDC substations. Besides 50/60 Hz capacitance and dissipation factor (power factor) measurements, the application gives valuable information about the general condition of any high voltage insulation by measuring its dielectric response. The technique is also capable of assessing the moisture content in oil/paper insulation systems.
CB101
Separate high voltage amplifier enables capacitance and dissipation factor measurements at 2 kV test voltage True and proven DFR/FDS technology for highest performance Large frequency range, DC to 1 kHz Compact design, weight < 5 kgVAX 020 expands the IDAX test voltage range from 200 V to 2 kV. This improves the capability to perform accurate measurements in extreme high interference environments e.g. HVDC substations. Besides 50/60 Hz capacitance and dissipation factor (power factor) measurements, the application gives valuable information about the general condition of any high voltage insulation by measuring its dielectric response. The technique is also capable of assessing the moisture content in oil/paper insulation systems.
70/120/160 kV DC
Lightest weight available in air-insulated high-voltage model Advanced performance with long-term reliability provided by filtered half-wave rectification Designed for maximum operator safety High Voltage DC Dielectric Test Sets provide the most dependable, portable DC highvoltage sources for checking the quality of electrical power cables, motors, switchgear, insulators, transformers and capacitors.
Megger MIT510/2
Measures up to 10 TΩ Selectable test voltage from 250 to 5000 VPI, DAR, DD testImproved productivity – operate from line power/mains if battery deadLi ion battery - extended capacity, rapid chargeCATIV 600 V safety ratingOffering CAT IV, the MIT515 is the simplest of Megger's new range of small light 5 kV insulation resistance testers for the testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.Now equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.
Megger MIT520/2
Measures up to 10 TΩ PI, DAR, DD, SV and ramp test Improved productivity operate from line power/mains if battery dead Li ion battery extended capacity, rapid charge Advanced memory with time/date stamp CATIV 600 V safety ratingOffering CAT IV, the MIT525 is compact, light 5 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.As well as measuring insulation resitance to 10 TΩ, the MIT525 also offers various diagnostic tests such as Polarisation index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.Now equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.
Megger S1-554/2
Now CAT IV, the S1-554/2 was designed specifically to assist you with the testing and maintenance of high voltage electrical equipment. The case is incredibly rugged and easy to carry, being made of tough polypropylene and achieving an ingress protection rating of IP65. In addition, the model number is marked on both the top and side of the case for ease of identification in stores or vehicles.As well as measuring insulation resitance to 15 TΩ, the S1-554/2 also offers various diagnostic tests such as Polarisation index, Dielectric Absorption Ratio, Step Voltage and Dielectric discharge.The instrument has a large easy to read backlit LCD display making it equally suitable for use in both bright unlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.
Megger MIT1020/2
Measures up to 20 TΩ PI, DAR, DD, SV and ramp test Improved productivity – operate from line power/mains if battery dead Li ion battery - extended capacity, rapid charge Advanced memory with time/date stamp CATIV 600 V safety ratingOffering CAT IV, the MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.As well as measuring insulation resitance to 20 TΩ, the MIT1025 also offers various diagnostic tests such as Polarisation index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.Now equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.
Megger S1-1052/2
CAT IV 600 V High output current 5 mA for fast charging of capacitive loads Testing up to 10 kV Mains or battery powered Digital/analogue backlit display Variable test voltage from 50 to 10000 V Automatic IR, PI, DAR, SV and DD tests Measures to 35 TΩ RS232 and USB download of resultsWhile this product is still available it will be superseded soon.For information about its replacement click here. Now CAT IV 600 V this new 10 kV insulation resistance testers from Megger are designed specifically to assist you with the testing and maintenance of high voltage electrical equipment. The case is incredibly rugged and easy to carry, being made of tough polypropylene and achieving an ingress protection rating of IP54. In addition, the model number is marked on both the top and side of the case for ease of identification in stores or vehicles.
Megger S1-1054/2
CAT IV 600 V Charge current: 5 mA 4 mA noise rejection and software filtering Mains or battery powered Digital/analogue backlit display Variable test voltage from 50 to 10000V Automatic IR, PI, DAR, SV and DD tests Measures to 35 TΩ RS232 and USB download of results to Megger Download Manager On board memory for results storageWhile this product is still available it will be superseded soon.For information about its replacement click here. Now CAT IV 600 V this new 10 kV insulation resistance testers from Megger are designed specifically to assist you with the testing and maintenance of high voltage electrical equipment in areas prone to high amounts of electrical noise.
MIT30
Rugged, compact, lightweight, and portableThe MIT30 is a 30 kV Insulation tester that has been developed to satisfy the demand for a variety of high voltage, high accuracy, low current applications in electrical distribution industries, aerospace and defense applications. The MIT30 cannot be used on grounded/earthed test samples. Otherwise, the unit will be damaged.The unit offers unparallel accuracy and resolution, with a high voltage output from 0 to 30 kV dc., trip levels from 0 - 360 μA and a resolution of 1 nA (±1.5%). The MIT30 represents excellent precision in a field instrument, and gives the operator confidence in the meaningful results.The MIT30 can be used to perform step-voltage and proof tests which, when incorporated into a routine maintenance program, can aid in predicting potential failure before breakdown occurs.
Megger S1-552/2
Now CAT IV, the S1-552/2 was designed specifically to assist you with the testing and maintenance of high voltage electrical equipment. The case is incredibly rugged and easy to carry, being made of tough polypropylene and achieving an ingress protection rating of IP65. In addition, the model number is marked on both the top and side of the case for ease of identification in stores or vehicles. As well as measuring insulation resitance to 15 TΩ, the S1-552/2 also offers various diagnostic tests such as Polarisation index, Dielectric Absorption Ratio, Step Voltage and Dielectric discharge. The instrument has a large easy to read backlit LCD display making it equally suitable for use in both bright unlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.