Products - Sinetec Technologies
Oscilloscpe,Analyzers,meters -LCR Meter & Impedance Measurement Product Accessor
Product Description
16060A Transformer Test Fixture
The 16060A provides a convenient means of measuring a transformers self-inductance, mutual inductance, turns-ratio, and dc resistance in the frequency range of dc to 100kHz, as appropriate for each measurement.
16034G SMD Test Fixture
Key Features & Specifications DUT Dimensions: (minimum applicable)0.6mm(L)x0.3mm(W) Measurement Instrument: 4192A, 4294A, 4263B, 4268A, 4278A, 4279A, 4284A, 4285A, E4980A Frequency: DC to 3 MHz (up to 110MHz with OPEN/SHORT/LOAD Compensation) DC Bias: -40V to +40V Operating Temperature: 0 to 55degC Terminal Connection: BNC, 4 terminal-pair Dimensions(approx.): 120(W) x 50(H) x 70(D)mm SMD Test Fixture Selection Table Description The 16034G is designed for impedance evaluations of SMD. The minimum SMD size that this fixture is adapted to evaluate is 0.6(L) x 0.3(W)[mm].
16034H SMD Array Type LCR Test Fixture
The 16034H is designed for impedance evaluations of array-type SMD.The minimum SMD size that this fixture is adapted to evaluate is 1.6(L)x0.8(W)[mm]. Since the tip of the measurement electrodes are very thin and the device holder is extremely flat, the device can be shifted and the measurement electrodes can contact each of the elements of the array-type component.
16089D Alligator Clip Lead (4 Clips)
Key Features & Specifications Frequency Measurement Instrument: 4192A, 4194A (Impedance Mode),4263B, 4278A, 4284A, 4285A and E4980A Frequency: 5Hz to 100kHz DC Bias: -35V to +35V Operating Temperature: 0 to 55degC Terminal Diameter: 5mm or less Clip: Four terminal (Agilentot,Hcur,Lpot, and Lcur) Cable Length: Approx. 0.94m (from connector to clip tip) Terminal Connection: BNC, 4 terminal-pair Description The 16089D makes it possible to measure odd-shaped components that cannot be measured with conventional fixtures. It is equipped with four alligator clips.
16451B Dielectric Test Fixture
The 16451B is used to evaluate the dielectric constant of solid dielectric materials accurately, and complies with ASTM D150. The 16451B employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixture.
16048A Test Lead (BNC Connector, with BNC Connector Board)
The 16048A test leads extend the measurement port with a 4 terminal-pair configuration. It is provided with a BNC female connector board to allow the attachment of user-fabricated test fixtures.
16048D 2m BNC Test Cable
The 16048A test leads extend the measurement port with a 4 terminal-pair configuration. It is provided with a BNC female connector board to allowThe 16048A test leads extend the measurement port with a 4 terminal-pair configuration. It is provided with a BNC female connector board to allow the attachment of user-fabricated test fixtures.the attachment of user-fabricated test fixtures.
16048E Test Leads
The 16048E test leads extend the measurement port with a 4-Terminal Pair configuration. It is provided with a BNC female connector board to allow the attachment of user-fabricated test fixtures.
16065C 40Vdc External Voltage Bias Adapter
The 16065C adapter is designed to operate specifically with the 4263A/B, 4268A and 4278A. By connecting an external DC voltage source to this adapter, a bias voltage of up to +/-40V can be supplied to a DUT. The DUT can be inserted by connecting any direct attachment 4 terminal-pair test fixture to the adapter.
16380C Capacitance Standard Set - 0.01uF to 10uF
The 16380C is a standard capacitor set consisting of three precision capacitors - 0.01uF (16385A), 0.1uF (16386A), 1uF (16387A),and an optional 10uF (16388A). These capacitors are primarily used for performance tests of Agilent's 4-terminal pair LCR meters and impedance analyzers. Refer to the instruments operation/service manual for the method of using these standards.
42030A Four Terminal Pair Standard Resistor Set
The 42030A is a standard resistor set consisting of nine precision resistor standards which range from 1 mΩ to 100 kΩ. These resistors are primarily used for performance tests of Agilents 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
16196B Parallel Electrode SMD Test Fixture, DC to 3 GHz
The 16196B surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements. The 16196 series SMD test fixtures are popular test accessories for use with the E4991A RF Impedance/Material analyzers.
16200B External DC Bias Adapter
The 16200B test fixture is designed to operate with high frequency LCR meters and impedance analyzers. It allows you to supply a bias current across the device of up to 5Adc through a 7mm port by using an external dc current source.
16190B Performance Test Kit
The 16190B is a performance test kit designed to verify the impedance measurement accuracy of LCR meters or impedance analyzers that have a 7 mm measurement terminal. Refer to the instruments operation/service manual for the method of using these standards.
16117B Low Noise Test Leads
The 16117B is designed to operate specifically with the 4339A/B. With its wide jaw clips (Option 003), it is capable of holding DUTs with large terminals. The clips can be replaced probes (Option 001) for measurements of small DUTs such as PC boards or IC sockets. Option 002 enables the construction of simple custom-made test leads. Electrical noise effects are reduced by the employment of shielded-cables. A built-in interlocking circuit enables safe high-voltage measurements. Note: 16117B Low Noise Test Leads is test leads only. Wide jaw clips, Alligator Clips and Add Soldering Sockets are options.
16339A Component Test Fixture
The 16339A is designed to operate specifically with the 4339A/B. It is provided with three component modules, which are used to hold SMD, lead and various type of devices. Electrical noise effects are reduced by the employment of a shielded case. A built-in interlocking circuit enables safe high-voltage measurements.
16118A Test Fixture
16118A is designed to operate specifically with the 4339A/B. It has tweezers' contacts, which makes it easy to hold SMD components. Electrical noise effects are reduced by the employment of shielded-cables. A built-in interlocking circuit enables safe high-voltage measurements. 16118A is designed to operate specifically with the 4339A/B. It has tweezers contacts, which makes it easy to hold SMD components. Electrical noise effects are reduced by the employment of shielded-cables. A built-in interlocking circuit enables safe high-voltage measurements.
16008B Resistivity Cell
The 16008B is designed to operate specifically with the 4339A/B High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials.
16117C Low Noise Test Leads
The 16117C is designed to operate specifically with the 4339A/B. It comes with a separate triaxial (special screw-type) female connector and a High Voltage BNC (special type) female connector, so that the terminal configuration of the 4339A/B can be converted to any other configuration. Therefore, custom-made test fixtures can easily be constructed.
16034E Test Fixture (SMD Components)
The 16034E test fixture is designed for impedance evaluations of SMD components. The minimum SMD size that this fixture is adapted to evaluate is 1.6(L) x 0.8(W) [mm].
16044A SMD LCR Kelvin Contact Test Fixture
The 16044A is designed for impedance evaluations of low impedance SMD of up to 10MHz. The minimum SMD size that this fixture is adapted to evaluate is 1.6(L)x0.8(W)[mm]. The 16044A has a Kelvin (4-Terminal) contact, which ensures repeatable measurements. It is also equipped with a mechanism for easily performing open and short compensation.
16047A Test Fixture (Axial and Radial)
The 16047A is designed for impedance evaluation of axial/radial lead type devices of up to 13MHz. The 16047A employs Kelvin contacts which realize a wide impedance measurement range. The contact tip can be changed according to the device shape.
16047D Test Fixture
The 16047D is designed for impedance evaluation of axial/radial lead type devices. The 16047D can be used up to a higher frequency, 40MHz.
16047E Test Fixture, 40 Hz to 110 MHz
The 16047E is designed for impedance evaluation of lead type devices up to 110 MHz. A guard terminal is available for three terminal devices and a shorting plate comes secured on this fixure.
16048G 1m Port Extention Cable for 4294A
The 16048G test leads extend the measurement port with a 4-Terminal Pair configuration. It is provided with a BNC male connector board to allow the attachment of user-fabricated test fixtures.
16065A 200 Vdc External Voltage Bias Fixture
The 16065A test fixture makes it possible to measure a DUT with up to +/-200V DC BIAS. The same modules of 16047A/D can be used to allow measurements of axial/radial lead components.
16089A Large Kelvin Clip Lead
The 16089A makes it possible to measure odd-shaped components that cannot be measured with conventional fixtures. It is equipped with two insulated Kelvin clips.
16089B Medium Kelvin Clip Lead
The 16089B makes it possible to measure odd-shaped components that cannot be measured with conventional fixtures. It is equipped with two insulated Kelvin clips.
16089C Kelvin IC Clip Lead
The 16089C makes it possible to measure odd-shaped components that cannot be measured with conventional fixtures. It is equipped with two insulated Kelvin clips.
16089E Kelvin Clip Leads
The 16089E test fixture can measure lead components with low impedance. It has excellent repeatability and low contact resistance. It is equipped with two insulated Kelvin clips.
16092A Spring Clip Fixture
The 16092A test fixure is designed for impedance evaluation of both lead and SMD components. It is furnished with two modules that can be readily screwed onto the plate to measure either lead or SMD components.
16092A Spring Clip Fixture
The 16092A test fixure is designed for impedance evaluation of both lead and SMD components. It is furnished with two modules that can be readily screwed onto the plate to measure either lead or SMD components.
16192A Parallel Electrode SMD Test Fixture
The 16192A test fixure is designed for impedance evaluations of side electrode SMD components. The minimum SMD size that this fixure is adapted to evaluate is 1(L)[mm].
16194A High Temperature Component Test Fixture
The 16194A is designed for measuring both axial/radial leaded devices and SMD within the temperature range from -55 to +200degC
16196A Parallel Electrode SMD Test Fixture, DC to 3 GHz
The 16196A surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, its easy to perform accurate and repeatable measurements.
16196C Parallel Electrode SMD Test Fixture, DC to 3 GHz
The 16196C surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements. The 16196 series SMD test fixtures are popular test accessories for use with the E4991A RF Impedance/Material analyzers. Applicable device sizes of the 16196 series Model Size code Specification of size L x W x H (mm) 16196A 0603 (inch) / 1608 (mm) (1.6 ± 0.15) x (0.8 ± 0.15) x (0.4 to 0.95) 16196B 0402 (inch) / 1005 (mm) (1.0 ± 0.1) x (0.5 ± 0.1) x (0.3 to 0.6) 16196C 0201 (inch) / 0603 (mm) (0.6 ± 0.03) x (0.3 ± 0.03) x (0.27 to 0.33) 16196D 01005 (inch) / 0402 (mm) (0.4 ± 0.02) x (0.2 ± 0.02) x (0.11 to 0.22)
16196D Parallel Electrode SMD Test Fixture, DC to 3 GHz
The 16196D surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements. The 16196 series SMD test fixtures are popular test accessories for use with the E4991A RF Impedance/Material analyzers. Applicable device sizes of the 16196 series Model Size code Specification of size L x W x H (mm) 16196A 0603 (inch) / 1608 (mm) (1.6 ± 0.15) x (0.8 ± 0.15) x (0.4 to 0.95) 16196B 0402 (inch) / 1005 (mm) (1.0 ± 0.1) x (0.5 ± 0.1) x (0.3 to 0.6) 16196C 0201 (inch) / 0603 (mm) (0.6 ± 0.03) x (0.3 ± 0.03) x (0.27 to 0.33) 16196D 01005 (inch) / 0402 (mm) (0.4 ± 0.02) x (0.2 ± 0.02) x (0.11 to 0.22)
16197A Bottom Electrode SMD Test Fixture
The 16197A is designed for impedance evaluations of bottom electrode SMDs. It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements. The Agilent 16197A supports various SMD sizes, as small as 1005 (mm)/0402 (inch) and as large as 3225 (mm)/1210 (inch). Accommodation of the 0603 (mm)/0201 (inch) size is available with option 001.
16201A 7 mm Terminal Adapter Kit
The 16201A terminal adapter converts the E5061B-3L5’s S-parameter test port to the 7 mm connector. The 16201A allows you to use 7 mm test fixtures with the E5061B-3L5.
16334A Test Fixture (Tweezers Contacts)
The 16334A is designed for impedance evaluations of SMD. The minimum SMD size that this fixture is adapted to evaluate is 1.6(L) x 0.8(W)[mm]. The tweezers contacts on this fixture makes it easy to hold the DUT.
16380A Standard Air Capacitor Set (1pF to 1000pF)
The 16380A is a standard capacitor set consisting of four precision capacitors - 1pF (16381A), 10pF (16382A) 100pF (16383A), 1000pF (16384A). These capacitors are primarily used for performance tests of Agilents 4-terminal pair LCR meters and impedance analyzers. Refer to the instruments operation/service manual for the method of using these standards.
16452A Liquid Test Fixture
Key Features & Specifications Frequency: 20 Hz to 30 MHz Measurement parameter: capacitance (C), dielectric constant (εr, εr) Liquid sample Quantity: ≤ 6.8 ml Description The 16452A provides accurate dielectric constant and impedance measurements of liquid materials. The 16452A employs the parallel plate method, which sandwiches the liquid material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixure.
16453A Dielectric Material Test Fixture
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.
16454A Magnetic Material Test Fixture
The 16454A is designed for accurate permeability measurements of toroidal-shaped magnetic materials. Since the construction of this fixture creates one turn around the toroid (with no magnetic flux leakage), the need of winding a wire around the toroid is unnecessary. Complex permeability is calculated from the inductance with and without the toroid. When the E4991A/4291B with option 002 is used as the measurement instrument, direct readouts of complex permeability are possible. In addition, it is furnished with a small and a large fixture to adapt to a wide range of sizes.
42090A Open Termination (4-Terminal Pair)
The 42090A is an open termination and is primarily used for performance tests of Agilents 4-terminal pair LCR meters and impedance analyzers. Refer to the instruments operation/service manual for the method of using this standard.
42091A Short Termination (4-Terminal Pair)
The 42091A is a short termination and is primarily used for performance tests of Agilents 4-terminal pair LCR meters and impedance analyzers. Refer to the instruments operation/service manual for the method of using this standard.
42941A Impedance Probe Kit, 40 Hz to 110 MHz
The 42941A Impedance Probe Kit used with the 4294A provides the capability to perform in-circuit measurements (printed circuit patterns, the input/output impedance of circuits, etc.) with better accuracy and wider impedance coverage from 40 Hz to 110 MHz. In-circuit measurements can improve cycle time in a design environment, or reduce the cost of rework in a production environment. The major specifications are listed below.
42942A Terminal Adapter, 40 Hz to 110 MHz
The 42942A terminal adapter converts the 4294A four terminal-pair configuration into a 7mm terminal configuration. As a result, test fixures with a 7 mm terminal connector can be used with the 4294A.
43961A RF Impedance Test Kit
The Agilent 43961A RF Impedance Test Kit provides the capability to measure impedance parameters of 1-port devices with the 4395A Option 010 (100 kHz to 500 MHz ) or the 4396B Option 010 ( 100kHz to 1. 8Ghz ). The test port or the 43961A is a 7-mm connector and can be used with the 16191A,16192A, or 16193A test fixure. The 43961A includes open/short/load calibration standards , and the test fixures such as 16192A are optional.
U1780A AC Power Adapter for Handheld Component Testers
The Agilent U1780A consists of an AC Power Adapter and power cord (according to country). The adapter is to be used with the U1700 Series Handheld Capacitor and LCR meters. This optional adapter enables users to power up their U1700 Series handhelds without using the meters supplied battery.
U1781A Alligator Clip Leads
The U1781A consists of a pair of alligator clip leads to be used with the U1700 handheld capacitor or LCR meters. They are shipped as standard with every unit of U1700 series meter.
U1782B SMD Tweezer
The Agilent U1782B is a tweezer to be used with the U1700 Series Handheld Capacitor and Handheld LCR Meters. For better noise immunity, the tweezer has a GUARD end to be connected to the meters GUARD terminal. The tweezer has redesigned with new shielded rigid cable to improve the usability and measurement stability.
U5481A IR to USB Cable
The U5481A enables the U1700 Series Handheld Capacitor or LCR Meters and U1401A Handheld Multifunction Calibrator/Meter to be easily connected to a PC for fast transfer of data.
U5481B IR to USB PC Connectivity Cable For Handheld LCR/Capacitance/Multifunction Calibrator Meter
The U5481B enables the U1700 Series Handheld Capacitor or LCR Meters and U1401A Handheld Multifunction Calibrator/Meter to be easily connected to a PC for fast transfer of data.
34420A Micro-Ohm Meter
7½ digit nanoVolt, micro-ohm meter is a high-sensitivity multimeter optimized for performing low-level measurements. It combines low-noise voltage measurements with resistance and temperature functions.